Korean J. Met. Mater. 2025;63(8):606-620. Published online 2025 Aug 5
DOI:
https://doi.org/10.3365/KJMM.2025.63.8.606
Abstract
This study investigated the effect of degree of ordering in Alloy 600 steam generator (SG) tube material on the initiation of primary water stress corrosion cracking (PWSCC), using a slow strain rate test (SSRT). The material was cooled in air from 1,100
oC to 550
oC, and below 550
oC the cooling rate.....